Special Precautions For Those Using Milicurie Quantities of P32

Low density shielding (e.g., Plexiglass, 3/8 inch) must be used to keep radiation to a minimum.

A mandatory radiation survey and wipe test must be performed after each use.

The use of finger type extremity monitoring for procedures that involve 1 millicurie or more.

The use of a dry run prior to the performance of unfamiliar procedures, in order to preclude unexpected complications.

Notification of Radiation Safety Officer that experiments are being conducted using 1 millicurie or more.

All experiments using 1 millicurie or more must be conducted in the radioisotope room.